Chat
Avatar
Assistance
🟢 Fast reply
CX2000 - Conductivity Transmitter/Controller

CX2000 - Conductivity Transmitter/Controller

Sonde pH redOx
CX2000 (Standard)
Our CX2000 is a fully-featured conductivity controller and 4-20mA transmitter for reading contacting conductivity sensors and programming process control. Set points are easily selected for 2 relay outputs and 1 wash control. Sensor calibration is simple with preset standards. The large LCD display features auto-sense back-light technology for use in all environments, including cooling tower controller applications. Reliable process control Lightning fast sensor calibration Perfect for use in all environments Compatible with a wide variety of sensors One year limited warranty Note: Transmitter is only compatible with sensors with tinned leads and either 30k NTC or Pt1000Ω RTD temperature compensation.
Select Outputs : 2x 4-20mA
En rupture de stock
1 608 €
TTC
Quantité

Rupture de stock

Our CX2000 is a fully-featured conductivity controller and 4-20mA transmitter for reading contacting conductivity sensors and programming process control. Set points are easily selected for 2 relay outputs and 1 wash control. Sensor calibration is simple with preset standards. The large LCD display features auto-sense back-light technology for use in all environments, including cooling tower controller applications.

  • Reliable process control: Two (2) adjustable Hi/Lo relay contacts
  • Lightning fast sensor calibration: Preset standards make sensor calibration quick and simple
  • Perfect for use in all environments: LCD display with auto-sense backlight technology & NEMA 4X, IP65 enclosure
  • Compatible with a wide variety of sensors: For use with all Sensorex contacting conductivity sensors
  • One year limited warranty: We stand behind all our products with the Sensorex Guarantee

Note: CX2000 Conductivity Controller and 4-20mA transmitter is compatible with sensors with tinned lead connectors and either 30k NTC or Pt1000Ω RTD temperature compensation.

CA ResidentsProp 65 WARNING(S)



  • Measuring Range:

    • Conductivity: 0.000 uS/cm -200.0 mS/cm in 5 ranges, 0.01/.01/1 uS/cm, 0.01/0.1mS/cm resolution, +/-1% Accuracy (+/- 1 digit)
    • Resistivity 0.00-20.00 MΩ • cm, 0.01 MΩ • cm resolution, +/-1% Accuracy(+/- 1 digit)
    • Temperature Range: -30 °C to 130 °C, 0.1 °C resolution, 0.2 °C accuracy

    Calibration Mode: Automatic with built-in standard solutions manual cell constant adjustment
    Cell Constants: 0.01, 0.05, 0.1, 0.5, 10/cm fixed or freely selectable 0.0080 – 19.99/cm
    Analog Output 1: Isolated DC 0/4 -20mA, corresponding to conductivity or resistivity. Max load 500 Ω.
    Analog Output 2: Isolated DC 0/4 -20mA, corresponding to temperature output. Max load 500 Ω.
    Set-Points: Contact: 240V AC, 5A max
    Activate: setpoints Hi/Low, Hi/Hi, Low/Low, ON/OFF
    Enclosure: NEMA 4X IP65, with push-button control pad. HWD: 96 mm (3.77”) x 132 mm (5.20”), 1/4 DIN
    Panel Cut-Out: 93mm (3.66”) x 93mm (3.66”)
    Weight: approx. 0.50kg (1.1lb)
    Mounting Options: Panel or Wall Mount
    Ambient Temperature: 0 ° C to 50 ° C
    Storage Temperature: -10 ° C to 70 ° C
    Temperature Compensation: NTC 30K or Pt1000 RTD with automatic compensation or manual
    Temperature Coefficient: Linear comp 0.00-40.00%, Non-linear comp for natural waters
    Power Requirement: 100-240V AC +/- 10%, 5W max, 50/60 H



Weight2.40 lbs
Dimensions11 × 10.5 × 7 in
Select Outputs2x 4-20mA, 1x 4-20mA + 1x MODBUS

Our CX2000 is a fully-featured conductivity controller and 4-20mA transmitter for reading contacting conductivity sensors and programming process control. Set points are easily selected for 2 relay outputs and 1 wash control. Sensor calibration is simple with preset standards. The large LCD display features auto-sense back-light technology for use in all environments, including cooling tower controller applications.

  • Reliable process control
  • Lightning fast sensor calibration
  • Perfect for use in all environments
  • Compatible with a wide variety of sensors
  • One year limited warranty

Note: Transmitter is only compatible with sensors with tinned leads and either 30k NTC or Pt1000Ω RTD temperature compensation.

: CX2000 (Standard)
En rupture de stock

Fiche technique

Power Requirement
100-240V AC +/- 10%, 5W max, 50/60 H
Coefficient de température
Linear comp 0.00-40.00%, Non-linear comp for natural waters
Cell Constants
0.01, 0.05, 0.1, 0.5, 10/cm fixed or freely selectable 0.0080 - 19.99/cm
Activate
setpoints Hi/Low, Hi/Hi, Low/Low, ON/OFF
Ambient Temperature
0 ° C to 50 ° C
Storage Temperature
-10 ° C to 70 ° C
Dimensions
11 x 10.5 x 7 in
Calibration Mode
Automatic with built-in standard solutions manual cell constant adjustment
Boîtier
NEMA 4X IP65, with push-button control pad.
H WD
96 mm (3.77") x 132 mm (5.20"), 1/4 DIN
Panel Cut-Out
93mm (3.66") x 93mm (3.66")
Analog Output 1
Isolated DC 0/4 -20mA, corresponding to conductivity or resistivity. Max load 500 Ω.
Analog Output 2
Isolated DC 0/4 -20mA, corresponding to temperature output. Max load 500 Ω.
Contact
240V AC, 5A max
Mounting Options
Panel or wall mount
Compensation de la température
NTC 30K or Pt1000 RTD with automatic compensation or manual
Select Outputs
2x 4-20mA, 1x 4-20mA + 1x MODBUS
Poids
2.40 lbs
approx. 0.50kg (1.1lb)